Item(s) Added To Your Bag

Metravi DT-9250 Digital TRMS AC|DC Clamp Meter

Click To Zoom

Metravi DT-9250 Digital TRMS AC|DC Clamp Meter

Metravi DT-9250 Digital TRMS AC|DC Clamp Meter

(Based On 10 Reviews)

The Metravi DT-9250 is a Digital AC TRMS/DC clamp meters with big jaw dia which can be used anywhere that high current and voltage measurements are needed. The unique feature of the DT-9250 is that it can measure Frequency through the Clamp Jaw, so it can measure the frequency at high current as well. It becomes very safe to take frequency measurements as you do not need to touch high current lines with probes to get frequency measurements.

Request Callback

Order In Bulk

Generate Quote

100% ORIGINAL Products Details

100% ORIGINAL Products

SECURE Payments Details

SECURE Payments

₹ 12,690.00

(GST inclusive price) i
  • Base Value: ₹ 10754.2
  • GST: (18) % ₹ 1935.8
  • Total Value ₹ 12690

₹12,690.00

( - 0% OFF )

Need Help ?

Our Client Care Managers Are On Call 24/7 To Answer Your Question.

Description

Key Features

  • Auto Power off
  • Auto/Manual Ranging
  • Data Hold
  • Peak Hold
  • True RMS
  • Clamp Jaw Dia: 2″ (52mm) approx
  • Display: 3-3/4 digits (4000 counts) Backlit LCD
  • DC Voltage: 400mV/4V/40V/400V/1000V
  • Accuracy: ± (1% + 3 digits)
  • AC Voltage T-RMS: 4V/40V/400V/1000V
  • Accuracy: ± (1.2% + 5 digits)
  • DC Current: 400A/2000A
  • Accuracy: ± (3.0% + 1A)
  • AC Current T-RMS: 400A/2000A
  • Accuracy: ± (3.0% + 2A)
  • Resistance: 400Ω/4kΩ/40kΩ/400kΩ/4MΩ/40MΩ
  • Accuracy: ± (1.0% + 4 digits)
  • Frequency (Through Terminal): 10Hz to 100kHz
  • Accuracy: ± (1.0% ±5 digits)
  • Duty Cycle: 0.1% to 99.9%
  • Accuracy: ± (1.2% + 5 digits)
  • Temperature: -20 to 1000°C
  • Accuracy: ± (2.0% + 5°C)
  • Peak of AC Current: 400A/2000A
  • Accuracy: ± (4.0% + 5 digits)
  • Capacitance: 4nF/40nF/400nF/4uF/40uF/400uF
  • Accuracy: ± (3.5% + 10 digits)
  • Diode and Continuity
  • CAT III 1000V, CAT IV 600V

 

What's in the box?

  •  Digital TRMS AC|DC Clamp Meter

Rating & Reviews

4.5
(Based On 10 Reviews)

Rating

0

0

0

0

0

Product Specifications

General Specification
Clamp Jaw Opening2” (52mm) approx
Display3-3/4 digits (4000 counts) Backlit LCD 
Continuity CheckBuzzer sound at less than (60±30)W
Diode TestTest current of 0.5mA typical;
Open circuit voltage <2VDC typical
Low Battery Indication‘ ‘ is displayed
Over-Range Indication‘OL’ display
Measurement Rate2 readings per second, nominal
PEAKCaptures peaks > 1ms 
Temperature SensorType K thermocouple
Input Impedance10MW (VDC and VAC)
Operating Temperature41°F to 104°F (5°C to 40°C)
Storage Temperature-4°F to 104°F (-20°C to 60°C) 
Operating HumidityMax 80% up to 87°F (31°C) decreasing linearly to
50% at 104°F (40°C)
Storage Humidity<80%
Operating Altitude 7000ft. (2000meters) maximum
BatteryOne (1) 9V Battery
Auto RangeAuto/Manual 
Auto Power OFF After approx. 15 minutes
Dimensions & Weigh27cm (H) x 10cm (W) x 4cm (D), 600 Grams Approx.
SafetyFor indoor use and in accordance with the
requirements for double insulation to IEC 1010-1
(2001) : EN61010-1 (2001) Over Voltage Category
III 1000V and Category IV 600V, Pollution Degree

 

Technical Specification
DC Voltage
RangeAccuracy
(% of reading + digits) 
Resolution
400mV ± (1% + 10 digit)0.1mV
4V1mV
40V10mV
400V100mV
1000V 1V

 

AC Voltage (T-RMS for DT-9250 Only)
RangeAccuracy
(% of reading + digits)
Resolution 
4V± (1.2% + 5 digit)1mV
40V10mV
400V100mV
1000V1V

 

AC Current (T-RMS for DT-9250 Only)
RangeAccuracy
(% of reading + digits)
Resolution 
400A± (3.0% +2A)100mA
2000A± (3.5% + 5 digit)1A

 

DC Current
RangeAccuracy
(% of reading + digits)
Resolution 
400A± (3.0% + 1A)100mA
2000A± (3.5% + 5 digt)1A

 

Resistance
RangeAccuracy
(% of reading + digits)
Resolution 
400Ω± (1.0% + 4 digit)0.1Ω
4kΩ± (1.5% + 4 digit)
40kΩ10Ω
400kΩ100Ω
4MΩ1kΩ
40MΩ± (2.0% + 4 digit) 10kΩ

 

Frequency (Auto-Ranging)
RangeAccuracy
(% of reading + digits)
10Hz to 100kHz± 1.0% ±5 digt

 

Frequency (Auto-Ranging)
RangeAccuracy
(% of reading + digits)
10Hz to 100kHz± 1.0% ±5 digt

 

Duty Cycle
RangeAccuracy
(% of reading + digits)
Resolution
(0.1% to 99.9%)± (1.2% + 5 digit) 0.1%

 

Temperature
RangeAccuracy
(% of reading + digits)
Resolution
(-20 to 1000°C)± (2.0% + 5°C)0.1°C
(-4 to 1832°F)± (3.0% + 9°C) 0.1°F

 

Continuity
Testing ConditionReading
Open voltage is approx.
0.5V
Buzzer makes a long
sound, While resistance is
less than (60±30W)

 

Peak of AC Current
RangeAccuracy
(% of reading + digits) 
Resolution
400A± (4.0% + 5 digit)100mA
2000A± (4.0% + 5 digit)1A

 

Capacitance
RangeAccuracy
(% of reading + digits)
Resolution 
4nF± (5.0% + 30 digt)0.1nF
40nF± (5.0% + 20 digt)1nF 
400nF ± (3.5% + 10 digt)10nF
4mF± (5.0% + 10 digt)100nF
40mF1mF
400mF10mF

 

Diode
Testing ConditionReading
Forward DCA is approx. 0.5mA,
backward Voltage is approx. 2V 
Forward voltage drop of
Diode